Sterilization MCQs
Practice Test
- ____ shows the time required for killing 90% of microbes present in a food sample.
- D Value
- F value
- Z value
- M value
- Which of the following is an efficient fpore size for bacterial filtration?
- 0.45 mm
- 0.22 mm
- 0.22 μm
- 0.54μm
- Zinc oxide powder is usually sterilized by,
- Autoclave
- Pasteurization
- Filtration
- Hot air oven
- The microorganism used as biological indicator for ionizing radiation is -------
- Clostridium sporogenes
- Bacillus subtilis
- Bacillus pumilus
- Bacillus stearothermophilus
- The microorganism used as biological indicator for nonionizing radiation is -------
- Clostridium sporogenes
- Bacillus subtilis
- Bacillus pumilus
- Bacillus stearothermophilus
- The microorganism used as biological indicator for gaseous sterilization is -------
- Clostridium sporogenes
- Bacillus subtilis
- Bacillus pumilus
- Bacillus stearothermophilus
- The microorganism used as biological indicator for autoclaving is -------
- Clostridium sporogenes
- Bacillus subtilis
- Bacillus pumilus
- Bacillus stearothermophilus
- The microorganism used as biological indicator for hot air oven is -------
- Clostridium sporogenes
- Bacillus subtilis
- Bacillus pumilus
- Bacillus stearothermophilus
- The microorganism used as biological indicator for sterilization by filtration is -------
- Pseudomonas diminuta
- Bacillus subtilis
- Bacillus pumilus
- Bacillus stearothermophilus
- Red heat is used for sterilization of,
- Surgical dressings.
- Disposable syringe
- Vaccines
- Nichrome wire loop
- Destruction of microbes on living tissues is----
- Antisepsis
- Sanitization
- Disinfection
- All of the above
- Exposure of material to steam of 100°C for 20 minutes for three consecutive days is -----
- Autoclaving
- Tyndallization
- Pasteurization
- None of the above.
- In the holder method, milk is sterilized by pasteurization method at -----
- 65°C for 30 mins
- 63°C for 30 mins
- 65 °C for 60 mins
- 63°C for 60 mins
- Brown’s tube is a most commonly used indicator for,
- Sterilization by filtration
- Sterilization by radiation
- Chemical sterilization
- Sterilization by heat
- Royce Sachet is an indicator for,
- Sterilization by filtration
- Sterilization by radiation
- Chemical sterilization
- Gaseous sterilization
- Chemical dosimeter is an indicator for,
- Sterilization by filtration
- Sterilization by radiation
- Chemical sterilization
- Sterilization by heat
- Antibiotic solutions are sterilized by,
- Sterilization by filtration
- Pasteurization
- Chemical sterilization.
- Sterilization by heat
- Disposable syringes are sterilized by,
- Sterilization by filtration
- Sterilization by radiation
- Chemical sterilization
- Pasteurization
- Z-value is defined as,
- the number of degrees (Celsius or Fahrenheit) required to change a D-value by ten folds.
- the number of degrees (Celsius or Fahrenheit) required to change a F-value by ten folds.
- the number of degrees (Celsius or Fahrenheit) required to change a D-value by two folds.
- the number of degrees (Celsius or Fahrenheit) required to change a F-value by two folds.
- F value for a process is,
- the number of minutes required to kill a known population of microorganisms in a given food sample under specified conditions.
- the number of minutes required to kill a 90% population of microorganisms in a given food under specified conditions.
- the number of minutes required to kill a 99% population of microorganisms in a given food under specified conditions.
- the number of degrees (Celsius or Fahrenheit) required to change a D-value by ten folds.
- Get link
- X
- Other Apps
Labels
Microbiology Pharmaceutics
Labels:
Microbiology
Pharmaceutics
- Get link
- X
- Other Apps